Victron MultiPlus-II 48/5000/70-50 Inverter
R9,573.91 including VAT
Order must be placed on this page to qualify for 2% EFT discount.
The Victron MultiPlus-II 48/5000/70-50 is a high-performance 5000VA hybrid inverter and charger combination engineered for 48V battery systems, delivering professional-grade power management, adaptive charging, and dependable backup security for residential and commercial energy storage installations.
PowerAssist & PowerControl: Dynamically safeguards limited grid or generator supplies from overloading by automatically reducing battery charging and supplementing deficits with battery power when required.
Uninterruptible AC Power: Operates as a true UPS with an ultra-fast transfer switch that engages in less than 20 milliseconds to keep sensitive electronics and critical loads running uninterrupted during grid failures.
IMPORTANT
The products we sell must be installed by a qualified electrician/technician and must adhere to local wiring regulations and standards. We are not liable for any damages or warranty rejections as a result of incorrectly installed products or systems.
The Victron MultiPlus-II 48/5000/70-50 is a sophisticated, multi-functional inverter/charger that brings together the proven capabilities of the original MultiPlus topology with a streamlined, modern design optimized for Energy Storage Systems (ESS). This 48V powerhouse seamlessly integrates a 5000VA true sine wave inverter, an advanced 70A adaptive battery charger, and a high-speed 50A AC transfer switch into a single, compact enclosure. Designed to serve as the core infrastructure for grid-tied backup, self-consumption optimization, or complete off-grid setups, it provides maximum flexibility and unmatched system stability.
At the heart of its operational efficiency are Victron’s proprietary PowerControl and PowerAssist features. These technologies monitor the total current drawn from the AC input source (such as a generator or a restricted grid connection). If an imminent overload is detected, the unit first lowers its battery charging current to prioritize the building's active loads. If demand still exceeds the source supply, the inverter instantly draws power from the connected 48V battery bank to supplement the shortfall. This allows the system to comfortably handle high-surge inductive loads, such as air conditioning units and pumps, without tripping supply circuit breakers or requiring an oversized generator.
The MultiPlus-II is engineered with dual AC outputs to facilitate smart energy distribution. The primary AC-out-1 output features full, no-break UPS functionality. In the event of an outage, the internal transfer switch takes over the loads so rapidly (under 20 milliseconds) that computers and critical infrastructure continue running without resetting. The secondary auxiliary output (AC-out-2) is active exclusively when a live AC input supply is present, ensuring that heavy-draw, non-essential appliances like water heaters or underfloor heating do not prematurely deplete your energy reserves during an extended power failure.
For large-scale or commercial installations, the system offers exceptional scalability. Up to six units can operate in parallel to scale up total power output, and three-phase or split-phase configurations can be effortlessly established using identical units. While this model does not include an onboard GX control hub, it features dual VE.Bus ports, allowing seamless connection to an external GX supervisor (such as a Cerbo GX or Ekrano GX). This integration provides comprehensive monitoring, firmware updates, and full system configuration via the free Victron Remote Management (VRM) portal. The MultiPlus-II is fully compatible with leading managed lithium battery brands as well as traditional lead-acid configurations.
Technical Specifications
Parameter
Specification
Nominal DC Input Voltage
48 VDC (Operating Range: 38 V – 66 V)
Continuous Output Power (25°C)
5000 VA / 4000 W
Continuous Output Power (40°C / 65°C)
3700 W / 3000 W
Peak Surge Power Capacity
9000 W
Maximum Efficiency
96%
Zero-Load Power (Normal Mode)
18 W
AC Input Voltage Range
187 – 265 VAC (Input Frequency: 45 – 65 Hz)
Integrated Transfer Switch Current
50 A
Maximum Battery Charge Current
70 A
Auxiliary AC Output (AC-out-2)
Yes (50 A)
Communication Interfaces
VE.Bus (x2), Programmable Relay, Current Sensor Port
The Victron MultiPlus-II 48/5000/70-50 is a high-performance 5000VA hybrid inverter and charger combination engineered for 48V battery systems, delivering professional-grade power management, adaptive charging, and dependable backup security for residential and commercial energy storage installations.
PowerAssist & PowerControl: Dynamically safeguards limited grid or generator supplies from overloading by automatically reducing battery charging and supplementing deficits with battery power when required.
Uninterruptible AC Power: Operates as a true UPS with an ultra-fast transfer switch that engages in less than 20 milliseconds to keep sensitive electronics and critical loads running uninterrupted during grid failures.